Technical data ‹red-y compact 2 series› | |||
Instrument types | |||
compact meter GCM Mass Flow Meter compact switch GCS Mass Flow Meter with Alarm Functions |
compact regulator GCR Mass Flow Meter with manual Valve compact all-in GCA Mass Flow Meter with Alarm Functions & Valve |
compact G½" versions
| |
Measuring ranges | |||
(full scale freely selectable) | Type | Measuring range (air) |
Process connection |
GCX-A GCX-B GCX-C GCX-D |
from 0 ... 50 mln/min to 0 ... 600 mln/min from 0 ... 600 mln/min to 0 ... 6000 mln/min from 0 ... 6 mln/min to 0 ... 60 ln/min from 0 ... 60 ln/min to 0 ... 450 ln/min |
G¼" G¼" G¼" G½" | |
Performance data | |||
Media (real gas calibration)
|
Air, O2*, N2*, He, Ar, CO2, H2, CH4, C3H8 (other gases and gas mixtures on request) *O2 & N2 are calibrated with air | ||
Accuracy (air & equivalents)
|
Eco: ± 2.0% of full scale; ranges > 200 ln/min ± 3.0% of full scale Special: ± 1.0% of full scale up to 50 ln/min | ||
Turndown ratio | Eco: 1 : 50 Special: 1 : 100 | ||
Response time | Max. 300 msec (depending on filter settings) | ||
Flow update by sensor | 40 msec (battery mode 500 msec) | ||
Display update | 240 msec (battery mode 500 msec) | ||
Repeatability | ± 0.5% of full scale | ||
Longterm stability | < 1% of measured value / year | ||
Power supply Meter GCM & Regulator GCR
|
Standard AA battery (lifetime in months depending on operation) or Micro-USB power supply (DIN 62684) Option: External power +8...30 Vdc (power consumption max. 120mA) | ||
Power supply Switch GCS & All-in GCA
|
External power +8...30 Vdc (power consumption max. 300mA) or Micro-USB power supply (DIN 62684) | ||
Operation pressure | 0.2 – 11 bar a | ||
Temperature (environment/gas) | 0 – 50°C | ||
Materials | Anodized aluminium, optional stainless steel electropolished | ||
Seals | FKM, optional EPDM (FDA) | ||
Pressure sensitivity | < 0.2% / bar of reading (typical N2) | ||
Temperature sensitivity | < 0.025% FS measuring range type / °C | ||
Warm-up time | < 1 sec. for full accuracy | ||
Integration | |||
Display
|
Touch display (128x64 px) with automatic position adjustment (position sensor) Backlighted only with external power supply (Micro-USB or 24 Vdc) | ||
Process connection | G¼" (BSPP* female) up to 60 ln/min, G½" (BSPP* female) up to 450 ln/min *British Standard Pipe Parallel | ||
Inlet section | None required | ||
Mounting orientation | Any position, consult manufacturer above 5 bar or vertical mounting | ||
Connection cable | For external power supply or alarm module: 2 m with fly leads | ||
Safety | |||
Test pressure | 16 bar a | ||
Leak rate | < 1 x 10-6 mbar l/s He | ||
Environmental protection | IP-50 | ||
EMC | EN 61326-1 | ||
Options | Panel Mounting Kit, Vacuum Fittings, Various Inlet and Outlet Fittings |
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com