Measuring Range in Air (l/min) | |||||
Range | Standard Configuration | ||||
Process connection | DN8 | DN15 | DN20 | DN25 | Absolute Pressure (mbar) |
Vacuum flow in l/min | 56 | 222 | 444 | 778 | 900 |
63 | 250 | 500 | 875 | 800 | |
71 | 286 | 571 | 1000 | 700 | |
83 | 333 | 667 | 1167 | 600 | |
100 | 400 | 800 | 1400 | 500 | |
125 | 500 | 1000 | 1750 | 400 | |
167 | 557 | 1333 | 2333 | 300 | |
250 | 1000 | 2000 | 3500 | 200 | |
500 | 2000 | 4000 | 7000 | 100 |
Stated measuring ranges for S418-V under following conditions:
• Standard flow in air in l/min
• Reference pressure: 1000 mbar
• Reference Temperature: +20 °C
Measurement |
| General data | ||||||
Flow | Configuration | |||||||
Accuracy | 1.5 % of reading ± 0.3 % FS | Wireless | S4C-FS App for mobile phones | |||||
Selectable units | m³/h, l/min, cfm, kg/h | PC Software | S4A PC software for data analyzes | |||||
Measuring range | see table on the previous page | Display | ||||||
Repeatability | 0.5 % of reading | Integrated | 4 digit LED | |||||
Sensor | Thermal mass flow sensor | Data Logger | ||||||
Sampling rate | 10 samples / sec | Storage | 8 Mio. values | |||||
Turndown ratio | 1:100 | Material | ||||||
Response time (t90) | 0.5 sec | Process connection | Aluminum alloy | |||||
Consumption | Housing | PC + ABS | ||||||
Selectable units | m³, ft3, l, kg | Sensor | Ceramic, glass coated | |||||
Pressure | Metal parts | Aluminum alloy | ||||||
Accuracy | 0.5 % FS | Miscellaneous | ||||||
Selectable units | bar, psi | Electrical connection | 2 x M8 (4 pole) | |||||
Measuring range | 0.01 ... 1.6 bar(a) | Protection class | IP54 | |||||
Sensor | Piezo resistive sensor | Approvals | CE, RoHS, FCC | |||||
Reference conditions | Process connection | G-thread | ||||||
Selectable conditions | 20 °C 1000 mbar (ISO1217) | Weight | 0.45 ... 1.1 kg (depends on model) |
Signal / Interface & Supply |
| Operating conditions | ||||||
Analog output | Medium | Air, N2, O2, CO2 and other gases | ||||||
Signal | 4 ... 20 mA (4-wire), isolated | Medium quality | ISO 8573: 4.4.3 or better | |||||
Scaling | 0 ... max flow, freely adjustable | Medium temperature | 0 ... 50 °C | |||||
Load | max. 250 Ohm | Medium humidity | < 90 % rH, no condensation | |||||
Update rate | 3/sec | Operating pressure | Max. 10 bar(g) | |||||
Pulse output | Ambient temperature | 0 ... 50 °C | ||||||
Signal | Switch output, normally open, max. 30 VDC, 200 mA | Ambient humidity | < 95 % rH | |||||
Scaling | 1 pulse per consumption unit | Storage temperature | -30 ... 70 °C | |||||
Fieldbus | Transport temperature | -30 ... 70 °C | ||||||
Protocol | Modbus/RTU | Pipe sizes | DN8, DN15, DN20, DN25 | |||||
Supply | ||||||||
Voltage supply | 15 ... 30 VDC | |||||||
Current consumption | 120 mA @ 24 VDC | |||||||
Data interface | ||||||||
Connection | USB micro |
Vacuum Scales | ||||
bar(a) | inch Hg(g) | kPa(g) | bar(g) | mbar(a) |
1.00 | 0.00 | 0 | 0.00 | 1000 |
0.90 | -2.95 | -10 | -0.10 | 900 |
0.80 | -5.91 | -20 | -0.20 | 800 |
0.70 | -8.86 | -30 | -0.30 | 700 |
0.60 | -11.81 | -40 | -0.40 | 600 |
0.50 | -14.77 | -50 | -0.50 | 500 |
0.40 | -17.72 | -60 | -0.60 | 400 |
0.30 | -20.67 | -70 | -0.70 | 300 |
0.20 | -23.63 | -80 | -0.80 | 100 |
0.10 | -26.58 | -90 | -0.90 | 100 |
0.01 | -29.24 | -99 | -0.99 | 10 |
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com