Measurement | |
Flow |
|
Accuracy | 2 % of reading ± 0.3 % FS |
Selectable units | m³/h, m³/min, l/min, l/s, cfm, kg/h, kg/min, kg/s |
Measuring range | see table below |
Repeatability | 0.25 % o.RDG |
Sensor | Thermal mass flow sensor |
Sampling rate | 3 samples / sec |
| Turndown ratio | 1:100 |
| Response time (t90) | 0.5 sec |
| Consumption | |
| Selectable units | m³, ft³, l |
| Reference conditions | |
Selectable conditions | 20 °C 1000 mbar (ISO1217) 0 °C 1013 mbar (DIN1343) freely adjustable |
| Signal / Interface & Supply | |
| Analog output | |
| Signal | 4...20 mA, isolated |
| Scaling | 0...max flow, freely adjustable |
| Load | Max. 250R |
| Update rate | 1/sec |
| Pulse output | |
Signal | Switch output, normally open, max. 30 VDC, 20 mA |
| Scaling | 1 pulse per consumption unit |
| Fieldbus | |
| Protocol | Modbus/RTU |
| Supply | |
| Voltage supply | 15...30 VDC |
Current consumption | 200 mA |
| General data | |
| Configuration | |
| Wireless | S4C-FS App for mobile phones |
| Material | |
| Process connection | Stainless steel 1.4404 (SUS 316L) |
| Housing | PC + ABS |
| Sensor | Ceramic, glass coated |
| Metal parts | Stainless steel 1.4404 (SUS 316L) |
| Miscellaneous | |
Electrical connection | A1415 : M12 (6 pole) other options : M12 (5 pole) |
| Protection class | IP65 |
| Approvals | CE, RoHS, FCC |
| Process connection | G1/2" (ISO 228/1) |
| Weight | 0.9 kg |
| Operating conditions | |
| Medium | Air, N2, O2, CO2 and other gases |
| Medium quality | ISO 8573 : 4.4.3 or better |
| Medium temperature | -30...+140 °C |
| Medium humidity | < 90 % rH, no condensation |
| Operating pressure | Max. 1.6 MPa(g) |
| Ambient temperature | -30...+70 °C |
| Ambient humidity | < 99 % rH |
| Storage temperature | -30...+70 °C |
| Transport temperature | -30...+70 °C |
| Pipe sizes | ½” ... 12” (bigger pipes on request) |