S450 Volumetric Flow Ranges | ||||
Inch | DN | S-Range (m3/h) | M-Range (m3/h) | HS-Range (m³/h) |
½” | DN15 | 0.2 ... 45.6 | 0.4 ... 91.0 | 0.48 ... 110 |
¾” | DN20 | 0.4 ... 89.1 | 0.9 ... 178 | 1.09 ... 215 |
1” | DN25 | 0.6 ... 148 | 1.2 ... 295 | 1.82 ... 357 |
1½” | DN40 | 1.5 ... 367 | 2.9 ... 732 | 4.36 ... 886 |
2” | DN50 | 2.4 ... 600 | 4.8 ... 1,198 | 7.26 ... 1,450 |
2½” | DN65 | 4.1 ... 1,027 | 8.2 ... 2,049 | 12.1 ... 2,480 |
3” | DN80 | 5.7 ... 1,424 | 11.4 ... 2,841 | 16.9 ... 3,442 |
4” | DN100 | 8.7 ... 2,183 | 17.4 ... 4,357 | 24.2 ... 5,275 |
5” | DN125 | 20 ... 3,419 | 38 ... 6,824 | 45.9 ... 8,263 |
6” | DN150 | 20 ... 4,930 | 39 ... 9,839 | 70.18 ... 11,913 |
8” | DN200 | 35 ... 8,786 | 70 ... 17,533 | 106.48 ... 21,229 |
10” | DN250 | 55 ... 13,744 | 110 ... 27,429 | 165.77 ... 33,210 |
12” | DN300 | 79 ... 19,815 | 158 ... 39,544 | 239.58 ... 47,880 |
Stated measuring ranges under following conditions:
• Standard flow in air
• Reference pressure: 1000 hpa reference temperature: +20 °c
• At other standard conditions and in other gases Flow ranges are different and data are available on request.
• In larger pipe diameters flow can also be measured.
Measurement | ||
Flow | ||
Accuracy | ±(1.5 % of reading + 0.3 % full scale) | |
Selectable units | m³/h, m³/min, l/min, l/s, cfm, kg/h, kg/min, kg/s | |
Repeatability | 0.25 % o.RDG | |
Sensor | Thermal mass flow sensor | |
Sampling rate | 3 samples / sec | |
Turndown ratio | 200:1 | |
Response time (t90) | 0.5 sec | |
Consumption | ||
Selectable units | m³, ft³, l, kg | |
Reference conditions | ||
Selectable conditions | 20 °C 1000 mbar (ISO1217), 0 °C 1013 mbar (DIN1343) freely adjustable |
Signal / Interface & Supply | ||
Analog output | ||
Signal | 4 ... 20 mA (4-wire), isolated | |
Scaling | 0 ... max flow, freely adjustable | |
Load | Max. 400 Ohm | |
Update rate | Value updated ever 1 sec | |
Pulse output |
| |
Signal | Switch output, normally open, max. 30 VDC, 200 mA | |
Scaling | 1 pulse per consumption unit (selectable) | |
Fieldbus | ||
Protocol | Modbus/RTU, HART, M-Bus | |
Supply | ||
Voltage supply | 16 ... 30 VDC | |
Current consumption | 200 mA |
General data | |||||
Configuration | |||||
PC Software | USB Service Kit + Software | ||||
Display | |||||
Integrated | LCD | ||||
Material |
| ||||
Process connection | Stainless steel 1.4404 (SUS 316L) | ||||
Housing | Al alloy | ||||
Sensor | Stainless steel 1.4404 (SUS 316L) | ||||
Metal parts | Stainless steel 1.4404 (SUS 316L) | ||||
Miscellaneous | |||||
Electrical connection | Screw terminals | ||||
Protection class | IP67 | ||||
Approvals | CE, RoHS, FCC, Ex-Options | ||||
Process connection | S450: G1/2” (ISO 228/1) S452: Measuring section with R-thread or Flange | ||||
Weight | S450: 1.75 kg S452: 1.25 kg (without measuring section) | ||||
Operating conditions |
| ||||
Medium | Air, N₂, O₂, CO₂ and other non corrosive gases | ||||
Medium temperature | S450: -40 ... +150 °C | ||||
Medium humidity | < 90 %, no condensation | ||||
Operating pressure | S450: 0 ... 1.6 MPa (applicable for option A1280) 0 ... 5.0 MPa (applicable for option A1279)* S452: 0 ... 4.0 MPa *For pressure above 1.5 MPa use the installation device A530 1106 or A530 1113. | ||||
Ambient temperature | -40 ... +65 °C | ||||
Storage temperature | -30 ... +70 °C | ||||
Transport temperature | -30 ... +70 °C | ||||
Pipe sizes | S450: ½” ... 12” (bigger pipes on request) S452: ½” ... 3” |
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com