Technical specifications | ||
Measuring range 1) | ULM–53_–01–_ ULM–53_–02–_ ULM–53_–06–_ ULM–53_–10–_ ULM–53_–20–_ | 0,1 ... 1 m 0,2 ... 2 m 0,2 ... 6 m 0,4 ... 10 m 0,5 ... 20 m |
Supply voltage | ULM–53N–_ _–_ ULM–53Xi–_ _ –I | 12 ... 36 V DC 12 ... 30 V DC |
Current supply | ULM–53N(Xi)–_ _ –I ULM–53N–_ _ –U ULM–53N–_ _ –M | 4 ... 20 mA / max. 22 mA max. 12 mA max. 20 mA |
Current output Voltage output Modbus output | ULM–53_–_ _ –I ULM–53N–_ _ –U ULM–53N–_ _ –M | 4 ... 20 mA (limit values 3.9 ... 20.5 mA) 0 ... 10 V (limit values 0 ... 10.2 V) Modbus RTU protocol |
Resolution | < 1 mm | |
Accuracy (within the total range) | ULM–53_–01 in area 0,1–0,2 m / 0,2–1,0 m ULM–53_–02; –06 ULM–53_–10; –20 | 0,3 % / 0,2 % 0,15 % 0,2 % |
Temperature error | max. 0,04% / K | |
Beamwidth (-3 dB) | ULM–53_–01–_ ; 02–_ ; 10–_ ULM–53_–06–_ ULM–53_–20–_ | 10° 14° 12° |
Ambient temperature range | ULM–53_–01–_ ; 02–_ ; 06–_ ULM–53_–10–_ ; 20–_ | -30 ... +70°C -30 ... +60°C |
Measuring period | ULM–53_–01–_; 02–_ ULM–53_–06–_; 10–_ ULM–53_–20–_ ULM–53_–_ _–M | 0,5 s 1,2 s 5,0 s adjustable via Modbus RTU |
Averaging (can be modified according to agreement) | ULM–53_ – _ _–_ ULM–53_–_ _–M | 4 measurement 3) adjustable via Modbus RTU |
Short time temperature stress resistance | +90°C / 1 hod. | |
Max. operation overpressure (on transmission surface) | 0,1 MPa | |
Max. internal values 2) (for the Xi version only) | Ui=30 V DC; Ii=132 mA; Pi=0,99 W; Ci=370 nF; Li=0,9 mH | |
Failure indication | echo failure – basic mode echo failure – inverse mode level in dead zone 4) – basic mode level in dead zone 4) – inverse mode | 3,75 mA / 0 V / Modbus RTU 22 mA / 10,5 V / Modbus RTU 22 mA / 10,5 V / Modbus RTU 3,75 mA / 0 V / Modbus RTU |
Protection class | ULM-53_-__-_-_-_- T ULM-53_-__-_-_- G-M, L ULM-53_-__-_-_- C-M, L ULM-53_-__-_-_- B-M, L ULM-53_-__-_-_- H-M, L | IP67 IP67 5) IP68 |
Recommended cable | PVC 2 x 0,75 mm2 (3 x 0,5 mm2; 2 x 2 0,25 mm2) | |
Maximal current output load resistance | at U = 24 V DC at U = 22 V DC at U = 20 V DC | Rmax= 270 Ω Rmax=180 Ω Rmax=90Ω |
Minimal voltage output load resistance | Rmin>1kΩ | |
Delay between supply power rise time and first measurement | ULM–53_–01–_ ; 02–_ ; 06–_ ULM–53_–10–_; 20–_ | 5 s 9 s |
Process connection | ULM–53_–01–_ ULM–53_–02–_ ULM–53_–06–_ ULM–53_–10–_ ULM–53_–20–_ | thread G ¾‘‘ thread G 1‘‘ thread G 1½‘‘ thread G 2¼‘‘ aluminium alloy flange |
Weight | ULM–53_–01–_ ULM–53_–02–_ ULM–53_–06–_ ULM–53_–10–_ ULM–53_–20–_ | 0,20 kg 0,20 kg 0,25 kg 0,65 kg 2,80 kg |