Technical specifications | ||
Supply voltage | GRLM–70N(T)–_ _ GRLM–70Xi(T)–_ _ GRLM–70Xt(T)–_ _ | 18 ... 36 V DC 18 ... 30 V DC 18 ... 33 V DC |
Output type | GRLM–70_–_ _-_-I GRLM–70_–_ _-_-M | 4 ... 20 mA with HART® RS-485 / Modbus RTU |
Current consumption | GRLM–70_–_ _-_-I GRLM–70_–_ _-_-M | 4 ... 20 mA / max. 22 mA type 10 mA / max. 30 mA |
Basic measurement accuracy (for reference reflecting surface) | ± 2 mm | |
Error of current output 2) | max. 80 μA | |
Resolution |
| 0,1 mm |
Maximal length of measuring electrode | GRLM–70_–10, 13 GRLM–70_–11 (12) GRLM–70_–20 GRLM–70_–30 (33,34,35) GRLM–70_–32 | 8 m 2 m 3 m 40 m 15 m |
Dead zone 3) | see instruction manual | |
Adjustable measuring range (SPAN) | min. 200 mm | |
Electrical parameters for variants Xi (XiT) – max. internal values | Ui =30 V DC; Ii =132 mA; Pi =0,99W; Ci =370 nF; Li =0,9 mH | |
Measurement sensitivity (8 degrees) | low (1) - medium (3) - high (5) - user (1 - 8) | |
Failure indication (echo loss) adjustable in modes | 3,75 mA, 4 mA, 20 mA, 22 mA, LAST4) | |
Damping | 1 ... 99 s | |
Rise time | approx. 60 s | |
Leakage resistance electrode - housing | 10 kΩ | |
Coupling capacity (housing - power) / dielectric strength | 5 nF/500 V AC | |
Maximal resistance of current output load Rmax for voltage - 24V DC / 22V DC / 20V DC | 270 Ω/180 Ω/90 Ω 5) | |
Maximum tensile strength of the rope electrode | 1400 kg 6) | |
Ambient temperature range 7) | -30 ... +70 °C | |
Process temperature range 7) | -40 ... +200 °C | |
Media temperature range 7) | -40 ... +300 °C | |
Process pressure (for temperature +85 °C) | GRLM-70N-10 (00, 20, 30, 33, 34, 35, 36, 37) GRLM-70N-11 (12, 13) GRLM-70N-32 | 0 ... 100 bar 0 ... 20 bar 0 ... 5 bar |
Protection class | IP67 |
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com