SPECIFICATIONS | OM004 | OM006 | OM008 |
Nominal Size: | 1/8" (4 mm) | 1/4" (6 mm) | 3/8" (8 mm) |
Flow* Range: | 0.26-9.5 GPH (1.0-36 L/hr) | 0.5-27 GPH (2-100 L/hr | 4-145 GPH (15-550 L/hr) |
Accuracy+ @ 3cp: | ± 1.0% of reading (accuracy is ± 0.2% of reading with optional RT14 with non-linearity correction) | ||
Repeatability: | Typically ± 0.03% of reading | ||
Temperature Range: | -40° F to +300° F (-40° C to +150° C) | ||
Pressure Rating (Threaded Meter): | |||
Aluminum | 220 psi (15 bar) | ||
316 Stainless Steel | 495 psi (34 bar) | ||
Intermediate Pressure Stainless Steel | 1450 psi (100 bar | ||
Recommended Filtration: | 200 mesh (75 µm | ||
Electrical: | |||
Output Pulse Resolution: | Pulses / gallon (Pulses / L) - Nomina | ||
Reed Switch | 10600 (2800) | 3975 (1050) | 1345 (355) |
Hall Effect | 10600 (2800) | 3975 (1050) | 2690 (710) |
QP - Quadrature Hall option | 10600 (2800) | 3975 (1050) | 2690 (710) |
HR - High Resolution Hall Effect | 42400 (11200) | 15900 (4200) | n/a |
Reed Switch Output | 30V (dc) x 200mA max. [maximum thermal shock 18o F (10o C) / minute | ||
Hall Effect Output (NPN) | 3 wire open collector, 5-24V (dc) max., 20mA max. | ||
Optional Outputs | 4-20mA, scaled pulse, quadrature pulse, flow alarms or two stage batch control |
*Maximum flow is to be reduced as viscosity increases, see flow de-rating guide.
Max recommended pressure drop is 14.5 psi (1 bar). +When used to meter rate, at very low flow rates, the rate can jump, due to resolution (not accuracy).
SPECIFICATIONS | OM015 | OM025 | OM040 | OM050 | ||
Nominal Size: | 1/2" (13 mm) | 1" (25 mm) | 1 1/2" (38 mm) | 2” (51 mm) | ||
*Flow Range: | 0.26-10.6 GPM (1-40 L/min) | 2.6-40 GPM (10-150 L/min) | 4-66 GPM (15-250 L/ min) | 8-118 GPM (30-450 L/ min) (SS) | ||
8-130 GPM (30-500 L/ min) (PPS) | ||||||
Accuracy @3cp: | ± 0.5% of reading (accuracy is ± 0.2% of reading with optional RT14 with non-linearity correction) | |||||
Repeatability: | Typically ± 0.03% of reading | |||||
Temperature Range: | -40° F to +300° F (-40° C to +150° C) refer to factory for lower temperature | |||||
Pressure Rating (Threaded Meter): | ||||||
Aluminum | 990 psi (68 bar) | 990 psi (68 bar) | 435 psi (30 bar) | 285 psi (20 bar) | ||
Intermediate Pressure Aluminum | n/a | 2000 psi (138 bar) | n/a | |||
316 Stainless Steel | 990 psi (68 bar | 990 psi (68 bar) | 435 psi (30 bar) | 550 psi (38 bar) | ||
Intermediate Pressure SS | 1450 psi (100 bar) | 1450 psi (100 bar) | 725 psi (50 bar) | 725 psi (50 bar) | ||
Pressure Rating (Mechanical Meter): | ||||||
Aluminum | 580 psi (40 bar) | 580 psi (40 bar) | 435 psi (30 bar) | 285 psi (20 bar) | ||
316 Stainless Steel | 580 psi (40 bar) | 580 psi (40 bar) | 435 psi (30 bar) | 285 psi (20 bar) | ||
Recommended Filtration | 100 mesh (150 μm) | |||||
Electrical: | ||||||
Output Pulse Resolution: | Pulses / gallon (Pulses / L) - Nominal | |||||
Reed Switch | 318 (84) | 120 (27) | 53 (14) | 25 (6.5) | ||
Hall Effect | 636 (168) | 405 (107) | 405 (107) | 99 (26) | ||
QP - Quadrature Hall Option | 636 (168) | 204 (54) | 106 (28) | 49 (13) | ||
Reed Switch Output | 30V (dc) x 200mA max. [maximum thermal shock 18o F (10o C) / minute | |||||
Hall Effect Output (NPN) | 3 wire open collector, 5-24V (dc) max., 20mA max. | |||||
Optional Outputs | 4-20mA, scaled pulse, quadrature pulse, flow alarms or two stage batch control |
*Maximum flow is to be reduced as viscosity increases, see flow de-rating guide. Max recommended pressure drop is 14.5 psi (1 bar).
SPECIFICATIONS | OM080 | OM080E | OM100 | OM100E |
Nominal Size: | 3” (80 mm) | 3” (80 mm) | 4”(100 mm) | 4”(100 mm) |
Nominal Flow* Range @ 3cP: | 10-200 GPM | 13-260 GPM | 20-400 GPM | 40-600 GPM |
35-750 L/min | 50-1000 L/min | 75-1500 L/min | 150-2500 L/min | |
Accuracy: | ±0.5% of reading (±0.2% of reading with optional RT14) | |||
Repeatability: | Typically ± 0.03% of reading | |||
Temperature Range: | -40˚F - +300˚F (-40˚C - +150˚C) | |||
Max. Pressure (Aluminum): | 175 psi (12 bar) | 175 psi (12 bar) | 145 psi (10 bar) | 145 psi (10 bar) |
Max. Pressure (Stainless Steel): | 175 psi (12 bar) | n/a | n/a | n/a |
Protection Class: | IP66/67 (NEMA 4X) Optional EXd I/IIB T3...T6, integral ancillaries can be supplied I.S. (Intrinsically Safe) | |||
Recommended Filtration: | 40 Mesh (400 μm) | |||
Electrical: | ||||
Output Pulse Resolution: | Pulses / gallon (Pulses / L) - Nominal | |||
Reed Switch: | 10.0 (2.65) | 5.68 (1.55) | 4.15 (1.10) | 2.1 (0.56) |
Hall Effect: | 40.5 (10.7) | 22.7 (6.00) | 16.6 (4.40) | 8.5 (2.24) |
QP Quadrature Hall Effect: | 20.0 (5.33) | 11.4 (3.00) | 8.3 (2.20) | 4.24 (1.12) |
Read Switch Output: | 30V (dc) x 200 mA max. (maximum thermal shock 18º F [10º C] / minute) | |||
Hall Effect Output: | 3 wire open collector. 5-24V (dc) max., 20 mA max. | |||
Optional Outputs: | 4-20 mA, scaled pulse, quadrature pulse, flow alarms or two stage batch control |
*Maximum flow is to be reduced as viscosity increases, see flow de-rating guide. Max recommended pressure drop is 14.5 psi (1 bar).