본문 바로가기 주메뉴 바로가기

제품소개

HOME > 제품소개 > Flow meter > 전자유량계

전자유량계

전자유량계

FLOW 33

  • 제조사 : COMAC CAL s.r.o
  • 제조국 : Czech Republic
•블루투스를 이용하여 셋팅가능
•다양한 전극과 라이닝 재질
•LED를 통한 상태표시
•방폭타입 제작가능
DOWNLOAD
제품목록

제품사양

 Power

 24V DC±15 % power with polarity reversal protection

 Input power

 4.2 VA

 Electrical connection

 through M12 (8-pin) connector

 Design

 compact

 Maximum fluid temperature


 90 °C (according to lining),

 for higher temperatures upon agreement with the manufacturer

 Diameter Nominal

 DN 4...600 (other DN upon agreement with the manufacturer)

 Lining material

 (lining maximum temperature)



 Rubber (hard, soft, with potable water test certificate): DN 25...DN 600 (Tmax 70 °C)

 PTFE: DN 10...DN 80 (Tmax 150 °C for separate version), PVDF: DN 4...DN 20 

 Rilsan: DN 25...DN 600 (Tmax 70 °C for separate version) 

 ETFE: DN 100...DN 600 (Tmax 150 °C), PFA, Ceramics (upon agreement with the manufacturer)

 Electrode material

 CrNi steel DIN 1.4571, Hastelloy C4, Titan, Tantalum

 Frame

 all-welded

 Sensor material


 flanged – stainless steel and structural steel with polyurethane coating

 sandwich, threaded, food grade – stainless steel 

 Process connection




 sandwich (PN25 only)

 flanged DIN (EN1092) – carbon or stainless steel

 threaded (EN 10226-1)

 food grade (DIN 11851 fitting, clamp)

 Pressure



 PN10 (DIN), PN16 (DIN), PN25 (DIN), PN40 (DIN), PN64 (DIN), PN100 (DIN)

 10K (JIS), 20K (JIS), 40K (JIS) 

 150lb (ANSI), 300lb (ANSI) 

 Measured fluid min. conductivity

 20 μS/cm (at a lower conductivity, upon agreement with the manufacturer)

 Flow meter measuring range (Qmin/Qmax)

 unidirectional/bidirectional for 0.2...12 m/s (1/60)

 Flow meter accuracy

 up to 0.5 %, repeatability up to 0.2 % 

 Pressure loss

 negligible

 Additional electrodes

 grounding and detection electrodes for empty piping (DN 15÷DN 600)

 Empty piping detection

 DN 10...DN 600

 Display 2x LED

 2× LED (meter‘s state is distinguished with 4 colours)

 Setting

 is done via Bluetooth (only for F33)

 Outputs (passive)



 OUT1 - impulse (max. 1,6 kHz, selectable constant)

 OUT2 - impulse (imp. constant as per OUT1)/status/flow-switch 

 Analogue 4...20 mA, adjustable range

 Max. ambient temperature

 55 °C

 Flow sensor degree of protection

 IP65, IP67, IP68


 

 Diameter

nominal

[mm]

 Qmin [m3/h]

dle Qmin / Qmax

 Qmax [m3/h]

 1/60

(0,2 m/s)

 –

(12 m/s)

 DN 4

 0,01

 0,6

 DN 6

 0,02

 1,2

 DN 8

 0,04

 2,2

 DN 10

 0,06

 3,4

 DN 15

 0,13

 7,6

 DN 20

 0,24

 14,2

 DN 25

 0,35

 21

 DN 32

 0,6

 34

 DN 40

 0,9

 54

 DN 50

 1,4

 84

 DN 65

 2,4

 144

 DN 80

 3,6

 220

 DN 100

 5,6

 340

 DN 125

 8,9

 534

 DN 150

 13

 760

 DN 200

 23

 1350

 DN 250

 35

 2115

 DN 300

 51

 3050

 DN 350

 70

 4150

 DN 400

 90

 5426

 DN 500

 141

 8480

 DN 600

 203

 12200



문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com