Power | 24V DC±15 % power with polarity reversal protection |
Input power | 4.2 VA |
Electrical connection | through M12 (8-pin) connector |
Design | compact |
Maximum fluid temperature | 90 °C (according to lining), for higher temperatures upon agreement with the manufacturer |
Diameter Nominal | DN 4...600 (other DN upon agreement with the manufacturer) |
Lining material (lining maximum temperature) | Rubber (hard, soft, with potable water test certificate): DN 25...DN 600 (Tmax 70 °C) PTFE: DN 10...DN 80 (Tmax 150 °C for separate version), PVDF: DN 4...DN 20 Rilsan: DN 25...DN 600 (Tmax 70 °C for separate version) ETFE: DN 100...DN 600 (Tmax 150 °C), PFA, Ceramics (upon agreement with the manufacturer) |
Electrode material | CrNi steel DIN 1.4571, Hastelloy C4, Titan, Tantalum |
Frame | all-welded |
Sensor material | flanged – stainless steel and structural steel with polyurethane coating sandwich, threaded, food grade – stainless steel |
Process connection | sandwich (PN25 only) flanged DIN (EN1092) – carbon or stainless steel threaded (EN 10226-1) food grade (DIN 11851 fitting, clamp) |
Pressure | PN10 (DIN), PN16 (DIN), PN25 (DIN), PN40 (DIN), PN64 (DIN), PN100 (DIN) 10K (JIS), 20K (JIS), 40K (JIS) 150lb (ANSI), 300lb (ANSI) |
Measured fluid min. conductivity | 20 μS/cm (at a lower conductivity, upon agreement with the manufacturer) |
Flow meter measuring range (Qmin/Qmax) | unidirectional/bidirectional for 0.2...12 m/s (1/60) |
Flow meter accuracy | up to 0.5 %, repeatability up to 0.2 % |
Pressure loss | negligible |
Additional electrodes | grounding and detection electrodes for empty piping (DN 15÷DN 600) |
Empty piping detection | DN 10...DN 600 |
Display 2x LED | 2× LED (meter‘s state is distinguished with 4 colours) |
Setting | is done via Bluetooth (only for F33) |
Outputs (passive) | OUT1 - impulse (max. 1,6 kHz, selectable constant) OUT2 - impulse (imp. constant as per OUT1)/status/flow-switch Analogue 4...20 mA, adjustable range |
Max. ambient temperature | 55 °C |
Flow sensor degree of protection | IP65, IP67, IP68 |
Diameter nominal [mm] | Qmin [m3/h] dle Qmin / Qmax | Qmax [m3/h] |
1/60 (0,2 m/s) | – (12 m/s) | |
DN 4 | 0,01 | 0,6 |
DN 6 | 0,02 | 1,2 |
DN 8 | 0,04 | 2,2 |
DN 10 | 0,06 | 3,4 |
DN 15 | 0,13 | 7,6 |
DN 20 | 0,24 | 14,2 |
DN 25 | 0,35 | 21 |
DN 32 | 0,6 | 34 |
DN 40 | 0,9 | 54 |
DN 50 | 1,4 | 84 |
DN 65 | 2,4 | 144 |
DN 80 | 3,6 | 220 |
DN 100 | 5,6 | 340 |
DN 125 | 8,9 | 534 |
DN 150 | 13 | 760 |
DN 200 | 23 | 1350 |
DN 250 | 35 | 2115 |
DN 300 | 51 | 3050 |
DN 350 | 70 | 4150 |
DN 400 | 90 | 5426 |
DN 500 | 141 | 8480 |
DN 600 | 203 | 12200 |