Basic technical data | |||
Working area (EN 60079-10-1) |
| no explosive hazard area | |
Supply voltage | 12 ... 34 V DC | ||
Current consumption | TFS-35N-_-_-PFPT-_ | 60mA for supply voltage U = 24V DC | |
TFS-35N-_-_-IFPT-_ | 60mA for supply voltage U = 24V DC + current loop | ||
Output | TFS-35N-_-_-PFPT-_ | 2 x transistor PNP with open collector | |
TFS-35N-_-_-IFPT-_ | 1 x transistor PNP with open collector | ||
Maximal resistance of current output load | 800 Ω for supply voltage U = 24V DC | ||
Indication of incorrect settings | 3,75 mA at current output + indication of bargraph | ||
Maximum switching current | 300 mA | ||
Maximum residual voltage in ON state | 1,5 V | ||
Temperature output - switching points | 15 °C; 30 °C; 45 °C; 60 °C; 75 °C | ||
Flow rate range | 1 to 150 cm/s (for water) | ||
Temperature gradient | < 250 K/min | ||
Isolating capacity (housing - inputs) / electrical strength | 4 nF / 350 V AC | ||
Protection | IP67 (variant C) | ||
Ambient working temperature range (ta) | -20 ... +80°C | ||
Cable | PVC 4x 0,5 mm2 | ||
Heat up time after start | 10s | ||
Response time | 2 to 15s *1) | ||
Pressure strength | 10 MPa ( 100 bar ) over full temperature range | ||
Weight of sensor (without cable) | 150 g |
● Depending on the flow rate and setting of the sensor.
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com