Series |
VH501 |
|
Comply with following technical specifications for railway applications: |
→ DIN EN 60077-1:2003 |
|
→ DIN EN 50125-1:2014 |
|
→ DIN EN 50216-5:2007 |
|
→ DIN EN 45545-2:2016 |
|
For oil flow monitoring |
|
For pipes DN 65...DN 100 [DN 25...DN 50 on Request] | |
High switching currents ->Microswitch is used as switching element | |
Optional : Cable gland selectable on three sides, flanged or threaded version | |
Technical data | |
Switching function | Change over contact or two change over contacts |
Setpoint* | Flanged version 6 m3/h at increasing flow for DN 65 pipes Threaded version 10 m3/h at increasing flow for DN 80 pipes |
Pressure rating [Test pressure] | Max. 10 bar [14 bar] |
Vibration proof IEC61373 | 4g |
Temperature ranges | |
Medium | -40...120 °C |
Ambient | -40...100 °C |
Storage | -40...100 °C |
Electrical data | |
Electrical connection | Direct cabeling, QC terminals 2.8 x 0.5 mm |
Max. contact rating | 48 VDC, 1 A resistive load |
110 VDC, 0.5 A resistive load / 0.2 A inductive load | |
250 VAC, 6 A resistive load | |
Degree of protection EN 60529 | IP68 and IP69K |
Terminal box | |
Surface finish | Powder coated RAL9006 |
Impact resistance | IK10 [10 Joule] |
Cable gland | M16 x 1.5 |
Cable diameter range | 4...11 mm |
Cable gland orientation | Location selectable on three sides |
* Other setpoint on request
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com