Technical specifications | |||||
HLM-16N | HLM25-N | ||||
Supply voltage (current/voltage output) | 10 ... 30 V DC / – | 10 ... 30 V DC / 15 ... 30 V DC | |||
Type output | 4 ... 20 mA | 4 ... 20 mA or 0 ... 10 V | |||
Pressure permissible overload | range 1 m H2O range 4 m H2O other ranges | 10x range | 40x range 25x range 10x range | ||
Basic error (of the total range) | range 1 m H2O range 4 m H2O other ranges | 0,5 % | 0,6 % 0,3 % 0,2 % | ||
Hysteresis, repeatability | 0,05 % | ||||
Long-term stability | 0,1 % / Year or 1cm H2O / Year | ||||
Temperature error | max. 0,04 % / K | ||||
Compensated temperature range (standard) | 0 ... +25 °C | ||||
Ambient temperature range (medium temperature) | Ranges > 20 m H2O Ranges ≤ 20 m H2O | 0 ... +50 °C | -25 ... +75 °C -25 ... +50 °C | ||
Maximal load resistance (for U = 24 V) | Rmax = 675 Ω | ||||
Protection class | IP68 | ||||
Used materials | Probe housing Membrane Hanging loop Cable isolation | AISI 316L AISI 316L - polyurethane | AISI 316L hastelloy C-276 stainless steel polyurethane | ||
Weight (without cable) | cca 0,45 kg | cca 0,6 kg |