Technical Data | |||
Measuring principle | Thin-film-on-steel | Accuracy @ 25°C typ. | ± 0.5 % FS typ. ± 0.3 % FS typ |
Measuring range | 0 ... 1 to 0 ... 1050 bar 0 ... 15 to 0 ... 15000 psi | Media temperature | –40°C ... +85°C |
Output signal | 4 ... 20 mA, 0.5 ... 4.5 VDC, 0 ... 5 VDC, 1 ... 5 VDC, 1 ... 6 VDC, 0 ... 10 VDC, 0.1 ... 10.1 VDC, 0.5 ... 4.5 VDC ratiometric | Ambient temperature
| –40°C ... +125°C (UL-rated Umgebungstemperatur: -20°C ... +80°C) details see section Electrical Connection |
NLH @ 25°C (BSL) typ. | ± 0.2 % FS typ. | Approval / conformity | EC79/2009: e1*79/2009*406/2010*00047*00 Ex zone 2 conformity acc. EN60079-0, EN60079-14, EN60079-7 |
Applications | H2 fuelling stations, Hydrogen compressors, Fuel cells, Vehicles with H2 drive, Hydrogen tanks |
문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com