Technical Data | |||
Measuring principle | Thin-film-on-steel | Accuracy @ 25°C typ. | ± 0.3 % FS typ. |
Measuring range | 0 ... 6 to 0 ... 700 bar 0 ... 100 to 0 ... 10000 psi | Media temperature | –40°C ... +85°C |
Output signal | 4 ... 20 mA, Switching output: 1 or 2 PNP transistors | Ambient temperature
| EN 50155: OT6 (–40°C ... +85°C) |
NLH @ 25°C (BSL) typ.
| ± 0.2 % FS typ. | Approval / conformity | EN 50155 (Railway) EN 45545-2 (Fire protection) EN 61373 (Shock, vibration) EN 50121-3-2 (EMC) |
Applications | Railways |