 OPERATING DATA
 Accuracy:
 DUM, DWM, RVM/U-1,
 RVM/U-2 and RVM/U-4
 ±3 % of full scale
 DKM-1, DKM-2 and DKME  ± 5 % of full scale  (with calibration at a specified viscosity)
 DKM-1, DKM-2 and DKME  ± 10 % of full scale  (viscosity compensated)
 DWM-L, RVM/U-L1,
 RVM/U-L2 and RVM/U-L4
 ± 10 % of full scale
 Operating temperature  -20 °C - 70 °C
 Storage temperature  -20 °C - 80 °C
 Repeatability  ±1 % of full scale

 

 

 POSSIBLE COMBINATIONS
 Type Sensor  Transmitter  Combination
 DUM  + DISPLAY  = DUM/DISPLAY
 DWM  + DISPLAY  = DWM/DISPLAY
 RVM/U-1  + DISPLAY  = RVM/U-1/DISPLAY
 RVM/U-2  + DISPLAY  = RVM/U-2/DISPLAY
 RVM/U-4  + DISPLAY  = RVM/U-4/DISPLAY
     
 DKM-1  + DISPLAY  = DKM-1/DISPLAY
 DKM-2  + DISPLAY  = DKM-2/DISPLAY
 DKME  + DISPLAY  = DKME/DISPLAY
     
 DWM-L  + DISPLAY  = DWM-L/DISPLAY
 RVM/U-L1  + DISPLAY  = RVM/U-L1/DISPLAY
 RVM/U-L2  + DISPLAY  = RVM/U-L2/DISPLAY
 RVM/U-L4  + DISPLAY  = RVM/U-L4/DISPLAY

 

 

 ELECTRICAL DATA  
 Operating Voltage  24 VDC (18...30 VDC)
 Power consumption  < 1 W

 Display

 

 

 

 Backlit transreflective LCD (32 x 16 Pixels)

 (Good readability in low light and in direct sunlight)
 Indication of value and dimension (unit selectable) Rotatable reading position

 (mechanical block limits the total range (< 360°))

 Analog output  4...20 mA (programmable)
 Current output (standard)  Max. load 500 Ω
 Voltage output (Please specify when ordering!)

 2(0)...10 V, Max. current 10 mA

 LED

 

 

 Signal-LED (red)
 signals a message on the display, e.g. a switch alarm

 (when the flow rate falls below or exceeds a limit value) or an error message)

 Switch output

 

 

 

 

 

 2 short-circuit proof and reverse-polarity protected switch outputs


 Alarm: Low / Cable break: Low / OK: High


 Push-pull-outputs
 The outputs are self-configuring and can be connected as PNP or
 NPN switch.
 The switch contacts can be programmed as Min- or Max-contacts.

 Load  Load in total max. 300 mA
 Hysteresis  Selectable (adjustable) in magnitude and direction

 Programming

 

 

 

 Programming by means of a programming ring (see operating instructions)
 Programmable features e.g.: hysteresis, span
 Programming protection by turning through 180° or

 by removing the programming ring

 Connection  For round plug M 12 x 1, 5 pin
 Ingress protection  IP 67


문의 031)243-1035
FAX 031)243-1025