본문 바로가기 주메뉴 바로가기

제품소개

HOME > 제품소개 > Flow Meter > 전자유량계

전자유량계

전자유량계

FLOW 38

  • 제조사 : COMAC CAL s.r.o
  • 제조국 : Czech Republic
•각 분야에 맞는 연결구 선택가능
•다양한 전극과 재질 및 출력
•간단한 작동법
•350도 회전 디스플레이
DOWNLOAD
제품목록

제품사양

 Power

 110...230 VAC (50/60 Hz), 24 VAC/VDC with polarity reversal protection

 Input power

 4.6 VA

 Type of electronics

 Head (H – standard), front (F), panel (P) versions

 Design

 Compact (Tmax 90 °C), separated (standard cable length 3 m)

 Diameter nominal

 DN 4...600 (other DN upon agreement with the manufacturer)

 Lining material




 Rubber (hard, soft, with potable water test certificate): DN 25...DN 600 (Tmax 70 °C)

​ PTFE: DN 10...DN 80 (Tmax 150 °C for separate version), PVDF: DN 4...DN 20 

 Rilsan: DN 25...DN 600 (Tmax 70 °C for separate version) 

 ETFE: DN 100...DN 600 (Tmax 150 °C), PFA, Ceramics (upon agreement with the manufacturer)

 Electrode material

 CrNi steel DIN 1.4571, Hastelloy C4, Titanium, Tantalum

 Frame

 All-welded

 Sensor material


 Flanged– stainless steel and structural steel with polyurethane coating

 Sandwich, threaded, food grade – stainless steel

 Process connections




 Sandwich (PN25 only)

 Flanged DIN (EN1092) – carbon or stainless steel 

 Threaded (EN 10226-1)

 Food grade (DIN 11851 fitting, clamp)

 Pressure



 PN10 (DIN), PN16 (DIN), PN25 (DIN), PN40 (DIN), PN64 (DIN), PN100 (DIN)

 10K (JIS), 20K (JIS), 40K (JIS)

 150lb (ANSI), 300lb (ANSI)

 Min. conductivity of the measured fluid

 20 μS/cm (at a lower conductivity, upon agreement with the manufacturer)

 Flow meter measuring range (Qmin/Qmax)

 bi-directional for 0.2 to 12 m/s (1/60); 0.12 to 12 m/s (1/100); 0.06 to 12 m/s (1/200)

 Flow meter accuracy

 Accuracy up to 0.5 %, repeatability up to 0.2 %

 Pressure loss

 Negligible

 Additional electrodes

 Grounding and detection electrodes for empty piping (DN 15...DN 600)

 Empty piping detection

 DN 10...DN 600

 Display unit

 LCD 2×16 characters

 Controls


 2× external button (viewing values)

 3× internal button (viewing + parameter changing)

 Outputs




 2x Impulse/flow switch (max. 400 Hz), 4...20 mA,

 Interface RS485 (protocols M-BUS/Mod-Bus)

 (Impulse and current outputs are passive with a possibility of being powered from

 internal power supply of the meter)

 Max. ambient temperature

 55 °C

 Flow sensor degree of protection

 IP65, IP67, IP68

 Electronics degree of protection

 Standard unit (H – head) – IP65, IP67, front unit (F) and panel unit (P) – IP54



Diameter

nominal

[mm]

 Qmin /Qmax  [m3/h]

  Qmax [m3/h]

 1/60

(0,2 m/s)

 1/100

(0,12 m/s)

 1/200

(0,06 m/s)

 (12 m/s)

 DN 4

 0,01

 -

 -

 0,6

 DN 6

 0,02

 -

 -

 1,2

 DN 8

 0,04

 -

 -

 2,2

 DN 10

 0,06

 0,034

 -

 3,4

 DN 15

 0,13

 0,076

 0,038

 7,6

 DN 20

 0,24

 0,142

 0,071

 14,2

 DN 25

 0,35

 0,21

 0,105

 21

 DN 32

 0,6

 0,34

 0,17

 34

 DN 40

 0,9

 0,54

 0,27

 54

 DN 50

 1,4

 0,84

 0,42

 84

 DN 65

 2,4

 1,44

 0,72

 144

 DN 80

 3,6

 2,2

 1,1

 220

 DN 100

 5,6

 3,4

 1,7

 340

 DN 125

 8,9

 5,34

 2,67

 534

 DN 150

 13

 7,6

 3,8

 760

 DN 200

 23

 13,5

 6,75

 1350

 DN 250

 35

 21,1

 

 2115

 DN 300

 51

 30

 –

 3050

 DN 350

 70

 41

 –

 4150

 DN 400

 90

 54

 –

 5426

 DN 500

 141

 –

 –

 8480

 DN 600

 203

 –

 –

 12200




문의 031)243-1035
FAX 031)243-1025
sales@gms-korea.com